Betekenis van:
fire station
fire station
Zelfstandig naamwoord
- a station housing fire apparatus and firemen
Synoniemen
Hyperoniemen
Voorbeeldzinnen
- The fire station is next to the police station.
- There was a fire near the train station last night.
- Fire station construction work
- In order to comply with the applicable regulations for fire fighting and rescue services it was necessary to provide the new southern runway with its own fire station.
- One indicating unit shall be located on the navigating bridge if the control panel is located in the main fire control station.
- Indication must be provided at the fire control panel in the continuously manned central control station whether each of the remote-controlled doors is closed.
- .5 In ships with a periodically unattended machinery space or when only one person is required on watch, there shall be immediate water delivery from the fire main system at a suitable pressure, either by remote starting of one of the main fire pumps with remote starting from the navigating bridge and fire control station, if any, or permanent pressurisation of the fire main system by one of the main fire pumps.
- Airport fire prevention and rescue services are one of the pre-conditions in order to obtain an operating licence. In order to comply with the applicable regulations for fire fighting and rescue services it was necessary to provide the new southern runway with its own fire station.
- .3.1 Hinged fire doors in stairway enclosures, main vertical zone bulkheads and galley boundaries which are normally kept open shall be self-closing and be capable of release from a central control station and from a position at the door.
- After such local opening the door shall automatically close again; .6 indication shall be provided at the fire door indicator panel in the continuously manned central control station whether each of the remote-released doors are closed;
- .5 All fire doors in stairway enclosures, main vertical zone bulkheads and galley boundaries which are normally kept open shall be capable of release from a central control station and from a position at the door.
- .3.2 A panel shall be placed in a continuously manned central control station to indicate whether the fire doors in stairway enclosures, main vertical zone bulkheads and galley boundaries are closed.
- The number and position of the hydrants shall be such that at least one jet of water may reach any part of the ship using one single maximum length of hose as given for class B ships in paragraph .7.2. .5 Every ship shall be fitted with at least one fire hose for every hydrant fitted. .6 In ships with a periodically unattended machinery space or when only one person is required on watch, there shall be immediate water delivery from the fire main system at a suitable pressure, either by remote starting of one of the main fire pumps with remote starting from the navigating bridge and fire control station, if any, or permanent pressurisation of the fire main system by one of the main fire pumps. .7 The delivery valve of each fire pump shall be fitted with a non-return valve.
- .6 indication shall be provided at the fire door indicator panel in the continuously manned central control station whether each of the remote-released doors are closed; .7 the release mechanism shall be so designed that the door will automatically close in the event of disruption of the control system or main source of electric power;
- .3 All doors, except fire doors which are normally kept closed, shall be capable of remote and automatic release from a continuously manned central control station, either simultaneously or in groups, and also individually from a position at both sides of the door.